CHOOSING THE RIGHT LOOP AMPLIFIER AND CABLE With the information gathered so far, it is now possible to specify the required hardware. If any of the results fall outside of the table, you will need to obtain specific guidance from the equipent manufacturer. For example, you might realise that a single turn loop in a large Cathedral is a category 1 design but powering it with a single ILD9 just won't work!!! You will need extra design help in this case! The following information is needed to use the table:
Using the following chart you can determine which amplifier will do the job. Note that for category 3 installations, you need two identical amplifiers.
Example
For example suppose you have a category 1 job 10m x 8m with an Aspect Ratio of 0.8.
For our example we could use an ILD122, ILD252 or ILD9 with the ILD122 being the smallest to do the job. You may wish to use a larger amplifier because of additional input facilities, or built in Metal Loss Corrector circuit. What you CANNOT do is to specify a SMALLER amplifier. Having chosen the amplifier, you need to specify the correct cable to use. The table below gives Minimum and Maximum wire lengths for each cable size when fitted to a particular amplifier.
The table gives you a simple set of guidlines to help select the right size cable for your installation. For an ILD60 for example, the MINIMUM length of 0.5mm˛ gauge cable is 6(m)eters and the maximum length is 38m. If you use a THICKER gauge of cable - 1.5mm˛ note that the MINIMUM length is now 17m and the maximum 65m. It's easier to fit a thin cable than a thick one so choose the thinnest size but MAKE SURE it is LONGER than the minimum length. Note that all the designs are for a SINGLE turn of wire. So for our example of a 10 x 8m room, the total wire length is 10 + 10 + 8 + 8 = 36m (note that for a category 3 design you must add up ALL the wire lengths). From the wire table we could use any cable between 0.75mm˛ and 2.5mm˛ or the flat tape if we used an ILD122 amplifier. Normal stranded cable can be used and a tri-rated one best of all as it has a higher temperature rating and will not degrade if close to heating pipes. You MAY use single insulated cables as there are no electrical safety issues. However, be careful not to abrade the cable during installation as a loop cable accidentally connected to earth will cause some VERY odd things to happen and will cause your loop amplifier to run hot or shut down. For this reason, cables with thicker or double insulation are preferred. That's it, amplifier specified, wire chosen, calculations done and verified. By using this process each time you can ensure that the hard of hearing never miss out because of poor loop design.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||